Gas Rate Calculator
Calculate Appliance Load (kW)
Select gas type, enter measured time and liters to calculate load.
| Appliance load | Gas rate (G25) |
|---|---|
| 24 kW full load | ~2,7 m³/h |
| 28 kW full load | ~3,2 m³/h |
| 35 kW full load | ~4,0 m³/h |
| 24 kW modulating (30%) | ~0,8 m³/h |
Calorific values: net CV (Hi) — Groningen gas 8.79 kWh/m³ (31.65 MJ/m³), G20 9.45 kWh/m³ (EN 437). Appliance nameplate load is specified on net CV; your energy bill uses gross CV (Hs, ~11% higher).
How to Measure Boiler Gas Consumption
To measure gas consumption, ensure only the target appliance is running. Read the gas meter, start a stopwatch, and read the meter again after a set period (e.g., 60 seconds). The difference in liters, combined with the gas calorific value, gives the burner load in kW.
Dutch Gas Types: G25 vs G20
The Netherlands is transitioning from low-calorific Groningen gas (G25, 8.79 kWh/m³ net CV) to high-calorific gas (G20, 9.45 kWh/m³ net CV). G20 has a higher energy content, so appliances consume less volume for the same heat output. Always verify which gas type your meter uses before calculating.