Expansion Vessel Calculator
EN 12828Calculate system volume and required expansion vessel size
Based on 16x2mm pipe (12mm inner diameter) = 0.113 L/meter
Calculation Breakdown
Henrad PDFHow This Calculator Works
This calculator determines the correct size of an expansion vessel for a central heating system. When water heats up, it expands - the expansion vessel absorbs this extra volume to prevent pressure buildup.
The Main Formula
Where:
Vreserve = max(3L, Vsystem × 0.5%)
η = (Pfinal - P0) / (Pfinal + 1)
Variables Explained
n = Expansion factor (depends on average water temperature)
P0 = Pre-charge pressure = 0.5 + (static height / 10) bar
Pfinal = Final working pressure = 2.5 bar
η = Vessel efficiency (usable volume ratio)
Floor Heating Calculation
Floor heating uses 16x2mm pipes, which means:
Inner diameter: 16 - 2 - 2 = 12mm
Volume per meter = π × r²
= π × (0.006m)² = 0.113 liters/meter
1 group (100m) = 100 × 0.113 = 11.3 liters
Floor heating typically runs at lower temperatures (35-45°C), so the expansion factor is calculated separately from radiators.
Expansion Factor Table
≤ 50°C → 1.21% ≤ 70°C → 2.27% ≤ 90°C → 3.59%
Radiator Data Source
For detailed radiator specifications including exact water content per type and size, refer to the official Henrad product documentation:
Henrad Panel Radiator Specifications (PDF)